Your application called fsync(). The kernel returned 0. Two seconds later the rack lost power, and the row your customer paid for was not in the database. No error was logged, no alert fired, and the backup was 40 minutes old. This is the single most common silent data-loss bug in production, and it is not a database bug — it is a misunderstanding of what fsync() actually promises.

fsync() does not put your bytes on the platter or in the NAND. It asks the kernel to hand the data to the storage device and wait for the device to report that it is persisted. If the device has a volatile write cache and nobody told it to flush that cache to media, the device can acknowledge the write while the data is still sitting in DRAM on the drive controller. Cut power at that instant and the write never happened — but every layer above it believed it did.

The fix is not “call fsync harder.” It is knowing which syscall gives you which guarantee, verifying that your drive honors cache flushes, and testing the failure path instead of hoping. This guide does all three with tools you can run today.

TL;DR — Quick Verdict

  • If you need durability for a database or a payment ledger: use fsync() (or fdatasync() when metadata is irrelevant), keep fsync=on, and verify the drive does not have a lying volatile cache. Anything else is a latency optimization that spends durability.
  • If you need fsync per write and want to know the real cost: benchmark with fio first — its --fsync=1 job is the cheapest way to discover that your cloud volume does 400 fsyncs/sec instead of 40,000.
  • If you want to prove your recovery path works: inject real lost writes with dm-flakey (drop_writes), then watch whether your database notices.
  • If you run PostgreSQL: run pg_test_fsync once per host before you tune anything. It measures the five wal_sync_method options on your filesystem in about 30 seconds.
  • Do not: trust sync_file_range(), trust barrier=0, trust synchronous_commit=off with money, or trust a benchmark run on a laptop NVMe to predict a network-attached cloud volume.

Syscall Semantics: What Each Call Actually Guarantees

Most teams lose data because they picked the wrong call from this table, or because they assumed two of these rows were equivalent.

CallFlushes dataFlushes file metadata (size, mtime)Flushes directory entryWaits for device cache flushTypical relative cost
fsync(fd)YesYesNoYes, if device supports flushHighest
fdatasync(fd)YesOnly what is needed to read the data backNoYesHigh (cheaper than fsync on ext4/XFS)
open(..., O_SYNC)Yes, per writeYes, per writeNoYes, per writeVery high — penalizes every write()
open(..., O_DSYNC)Yes, per writeOnly size-relevant metadataNoYes, per writeHigh
sync_file_range(fd)Starts writebackNoNoNoCheap — not a durability call
syncfs(fd)Yes, whole filesystemYesYesYesHighest, unscoped
msync(addr, len, MS_SYNC)Yes, mapped pagesDependsNoYesHigh

Two rows deserve a warning label. sync_file_range() is a writeback scheduling hint — it is legal for the kernel to return before anything reaches the device, and it does not order metadata. Code that replaced fsync() with sync_file_range() for “performance” is not durable, full stop. And O_SYNC on every write() is usually slower than batching writes and calling fdatasync() once, because it forces a device flush per syscall instead of per transaction.

The second thing the table hides: fsync() on a file does not persist the file’s name. If you write a temp file and rename() it into place, you must also fsync() the parent directory, or a crash can leave you with the new content on disk and the old directory entry — or no entry at all.

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
int fd = open("/var/lib/app/data.tmp", O_WRONLY | O_CREAT | O_TRUNC, 0644);
write(fd, buf, len);
fsync(fd);          /* content is durable */
close(fd);

rename("/var/lib/app/data.tmp", "/var/lib/app/data.bin");

int dfd = open("/var/lib/app", O_RDONLY | O_DIRECTORY);
fsync(dfd);         /* the rename itself is durable */
close(dfd);

Skip that last fsync(dfd) and you have written a durable file that nothing can find after a crash. It is the most common filesystem-level mistake in hand-rolled storage code, and it is invisible in testing because the page cache keeps the name alive until the machine dies.

Why a Device Can Acknowledge a Write It Has Not Persisted

A modern drive is a small computer. It has DRAM (or SRAM) cache, a firmware scheduler, and a mapping table. When the kernel issues a write, the drive can accept it into that cache and report completion immediately. Its volatile write cache is exactly what makes it fast — and exactly what makes your fsync() a lie if the cache is not flushed.

The kernel’s defense is the cache flush command (ATA FLUSH CACHE, SCSI/NVMe FLUSH). fsync() triggers it, but only if the block layer believes the device needs it. That belief comes from the device’s advertised capabilities, and it can be wrong in both directions:

  • Write cache enabled but not advertised (cheap USB bridges, some virtual disks): the kernel skips the flush, the drive keeps lying.
  • Flush advertised but ignored (firmware bugs, some RAID controllers with a “write-back” policy and no battery): the flush returns success without doing anything.
  • Filesystem barriers disabled by an admin chasing benchmark numbers (barrier=0 on ext4, nobarrier on XFS, noflush style options elsewhere): the filesystem stops emitting flushes entirely.

Check the device before you write a single line of durable code:

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
# ATA/SATA: is the write cache on?
sudo hdparm -W /dev/sda
# /dev/sda:
#  write-caching =  1 (on)

# NVMe: does the controller advertise a volatile write cache? (VWC bit)
sudo nvme id-ctrl /dev/nvme0 | grep -i vwc
# vwc       : 0x1

# SMART view for SATA, including cache state as the firmware reports it
sudo smartctl -i /dev/sda | grep -i -A1 "write cache"

If vwc is 0x1 on NVMe, a flush is mandatory and fsync() is doing real work — which is also why your write latency is bound by flush latency, not by bandwidth. If hdparm -W reports the cache is on for a drive that has no power-loss protection, you are one hdparm -W 0 (or one uninterruptible power supply) away from a durable system.

On ext4 there is one more detail worth knowing: since kernel 4.13, writeback errors are tracked per file and a failed fsync() returns EIO, and subsequent fsync() calls on the same file also return EIO instead of silently succeeding. Before that change, a failed writeback could be reported once and then forgotten. If your code ignores fsync() return values, you are discarding the only signal the kernel gives you.

Tool 1: fio — Measuring the Real Cost of Durability

fio (6,436 stars, last pushed 2026-11-20) is the reference I/O workload generator, and it is the only realistic way to find out what a flush costs on your hardware instead of guessing from a spec sheet. Install it from your distribution (apt install fio, dnf install fio, apk add fio) — it has no runtime dependencies worth mentioning.

A job that does one 4 KiB random write followed by one fsync, with O_DIRECT to bypass the page cache:

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
[global]
ioengine=libaio
direct=1
filename=/mnt/test/durability.dat
size=512M
iodepth=1
runtime=60
time_based=1

[fsync-per-write]
rw=randwrite
bs=4k
fsync=1

fsync=1 means “issue an fsync after every 1 write operation”. Compare it against the same job with fdatasync=1, and against a variant with no sync at all. The gap between the third and the first is your durability tax, and it is routinely two to three orders of magnitude on network-attached block storage.

1
2
3
fio --name=durability --filename=/mnt/test/fio.dat --size=512M \
    --bs=4k --rw=randwrite --iodepth=1 --fsync=1 \
    --ioengine=libaio --direct=1 --runtime=60 --time_based

Then verify rather than assume — this is the part almost nobody runs. A verification job writes a known pattern, forces flushes, and checks every block on a second pass:

1
2
3
fio --name=verify-durability --filename=/mnt/test/verify.dat --size=512M \
    --bs=4k --rw=randwrite --fsync=1 --verify=crc32c \
    --verify_fatal=1 --ioengine=libaio --direct=1

--verify_fatal=1 makes fio stop on the first mismatch instead of continuing. If you run this on a device that lies about flushes and you cut power mid-run, you get the names of the blocks that vanished — which is exactly the evidence your storage vendor will ask for and exactly the evidence most teams cannot produce.

For a broader picture of what the same box does under sequential, random, and mixed load, our storage benchmarking walkthrough covers the job files worth keeping in a repo.

Tool 2: dm-flakey — Injecting the Power Cut You Cannot Schedule

You cannot ask a cloud provider to yank the power at the exact microsecond you want. You can, however, make the block layer drop writes on a schedule. The device-mapper flakey target does precisely that: it presents a working device, then periodically stops honoring writes.

1
2
3
4
5
6
7
# Writes are accepted for 600s, then silently dropped for 60s, repeatedly.
# "drop_writes" behaves like a power loss with a lost write cache:
# the I/O completes successfully and the data never lands.
SECTORS=$(blockdev --getsz /dev/sdb1)
sudo dmsetup create flakey-test --table \
  "0 $SECTORS flakey /dev/sdb1 0 600 60 1 drop_writes"
sudo mkfs.ext4 /dev/mapper/flakey-test

The drop_writes feature is the important one. The alternatives tell a different story: error_writes returns EIO (a polite failure your application can handle), corrupt_bio_byte flips a byte (good for checksum testing), and no feature at all just truncates the device (good for simulating a smaller disk). Real power loss is drop_writes, because real power loss is silent.

Run your database on the flakey device for ten minutes, kill it during a down window, remount, and see what the recovery path does. Two outcomes are acceptable: the database starts and the last committed transaction is present, or the database starts, reports lost transactions loudly, and is consistent. One outcome is not: the database starts silently with a torn page or a half-written WAL record. That third outcome is how people discover their full_page_writes setting is off during an incident instead of during a test.

1
2
3
sudo dmsetup suspend flakey-test
sudo dmsetup resume flakey-test
sudo dmsetup remove flakey-test

Clean up with remove when you are done, and never leave a flakey device in /etc/fstab on a machine you care about.

If you use this to test a filesystem rather than a database, pair it with a real integrity check afterwards — our fsck, xfs_repair and btrfs check guide covers which tool is authoritative for which filesystem and which ones can make things worse.

Tool 3: pg_test_fsync — The Five Ways PostgreSQL Can Flush

PostgreSQL exposes wal_sync_method with five platform-dependent values, and the difference between them on a given filesystem is not something to guess. pg_test_fsync ships with PostgreSQL (so it is already installed on every database host you own) and measures each method for a few seconds.

1
sudo -u postgres pg_test_fsync -s 3 -f /var/lib/postgresql/18/main

Sample output shape (your numbers will differ — that is the entire point):

1
2
3
4
5
6
7
Compare file sync methods using one 8kB write:
(in wal_sync_method preference order, except fdatasync is Linux's default)
        open_datasync                      1821.443 ops/sec
        fdatasync                          1794.006 ops/sec
        fsync                              1204.882 ops/sec
        fsync_writethrough                  not supported
        open_sync                          1103.517 ops/sec

Read it as: on this filesystem, open_datasync and fdatasync were roughly 50% faster than fsync, because fsync also pushes an inode metadata update that a WAL append does not need. On most Linux filesystems the default fdatasync is already the right answer; on some network filesystems the ranking inverts. The concrete rule: pick the fastest method that is actually durable, and re-run this after any storage migration. A tuning decision copied from a blog post about ext4 on local NVMe is not a tuning decision.

While you are on the host, confirm the settings that make fsync meaningful:

1
2
3
4
SHOW fsync;               -- must be on. off means "corrupt me".
SHOW full_page_writes;    -- must be on.
SHOW synchronous_commit;  -- on/remote_apply for money; off buys latency with durability.
SHOW wal_sync_method;     -- whatever pg_test_fsync says is fast AND durable

synchronous_commit = off is a legitimate setting for analytics or session data. It is not legitimate for a ledger: the server acknowledges the commit before the WAL is flushed, so a crash loses the last window of transactions (bounded roughly by wal_writer_delay, default 200 ms, but larger under write pressure). The performance win is real — often 2-3x on write-heavy transactions — which is exactly why it gets enabled by accident and discovered during a postmortem.

Application-Level Durability: What Your Frameworks Actually Promise

The syscall layer is only half the story; your language runtime and database driver decide which call gets used and when.

Python — the stdlib gives you all three levels, and the directory fsync too:

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
import os

path = "/var/lib/app/data.bin"
tmp = path + ".tmp"

fd = os.open(tmp, os.O_WRONLY | os.O_CREAT | os.O_TRUNC, 0o644)
try:
    os.write(fd, payload)
    os.fdatasync(fd)          # data + size, skips mtime/atime
finally:
    os.close(fd)

os.replace(tmp, path)

dfd = os.open("/var/lib/app", os.O_RDONLY | os.O_DIRECTORY)
try:
    os.fsync(dfd)             # persist the rename
finally:
    os.close(dfd)

Go — File.Sync() maps to fsync(2), so it is the strong version:

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
f, err := os.OpenFile(tmp, os.O_WRONLY|os.O_CREATE|os.O_TRUNC, 0o644)
if err != nil { return err }
if _, err := f.Write(payload); err != nil { return err }
if err := f.Sync(); err != nil { return err }   // fsync
if err := f.Close(); err != nil { return err }
if err := os.Rename(tmp, path); err != nil { return err }

d, err := os.Open(filepath.Dir(path))
if err != nil { return err }
defer d.Close()
return d.Sync()                                  // persist the rename

Rust — sync_data() is fdatasync, sync_all() is fsync. Choosing sync_data() for an append-only log is a free win:

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
use std::fs::{File, OpenOptions};
use std::io::Write;
use std::path::Path;

fn append_durable(path: &Path, bytes: &[u8]) -> std::io::Result<()> {
    let mut f = OpenOptions::new().create(true).append(true).open(path)?;
    f.write_all(bytes)?;
    f.sync_data()?;      // fdatasync: no inode metadata flush
    Ok(())
}

SQLite — the defaults are safer than most people assume, and the “fast” settings are the dangerous ones:

1
2
3
4
PRAGMA journal_mode = WAL;      -- better concurrency
PRAGMA synchronous = FULL;      -- fsync on every commit (default, durable)
-- PRAGMA synchronous = NORMAL; -- WAL: durable against app crash, NOT against power loss
-- PRAGMA synchronous = OFF;    -- benchmark-only. Never in production.

WAL + synchronous=NORMAL is a reasonable choice for a cache or a session store. It is not reasonable for anything you would restore from backup after losing it.

The Five Durability Traps That Actually Bite

  1. Testing durability on the wrong storage. Local NVMe can complete an fsync in tens of microseconds; a network-attached cloud volume can take milliseconds. Same code, same filesystem, 50x different commit latency. Benchmark where you deploy.
  2. sync_file_range() in place of fsync(). It is a writeback hint. It does not wait, it does not order metadata, and it will happily return before your data reaches the device.
  3. Forgetting the directory fsync after rename(). File content durable, filename gone. Add the O_DIRECTORY fsync.
  4. Mount options that disable barriers. barrier=0, nobarrier, or a hypervisor cache mode like cache=unsafe removes the flush entirely. Someone enabled it to make a benchmark look good; the bill arrives as a corrupted database.
  5. Trusting a RAID controller’s write-back cache without a battery or capacitor. A controller advertising write-back with no power-loss protection has the same failure mode as a lying drive, and it is much harder to detect because the drives themselves look honest.

One more, specific to containers: O_DIRECT on tmpfs is silently ignored, and tmpfs has no durability at all. A --direct=1 fio run against /dev/shm measures nothing. The same is true of many overlay filesystems in ways that depend on the backing store — check what your container runtime actually mounted before you trust a benchmark.

FAQ

Does fsync() guarantee data is on physical media?

No. It guarantees the kernel issued a cache-flush command to the block device and the device reported completion. If the device has a volatile write cache that ignores or misreports flushes — some USB bridges, some RAID controllers, some virtual disks — the data can still be lost on power failure. fsync() plus a device that honors FLUSH is durability; fsync() alone is a request.

Is fdatasync() faster than fsync(), and is it safe?

On ext4 and XFS, fdatasync() is usually measurably faster because it skips the inode metadata update that fsync() forces (mtime, atime). It is safe whenever you only need the file’s content and size to survive — appending to a WAL or a log file is the canonical case. If you rely on metadata such as permissions or timestamps surviving, use fsync().

Why did my database lose the last transactions after a power cut?

Three usual causes, in order of frequency: synchronous_commit = off (PostgreSQL) or PRAGMA synchronous = NORMAL in WAL mode (SQLite), both of which acknowledge commits before the flush completes; a storage stack with a volatile cache that does not honor flushes; or an application-level write path that never called fsync() on the file or the parent directory at all.

Can I disable the write cache to make fsync() honest?

Yes — hdparm -W 0 on SATA, or disable the controller cache in firmware — but expect write throughput to collapse, often by an order of magnitude, because every write now waits for media. The better answer is a device with power-loss protection (enterprise SSD with capacitors, or a RAID controller with a battery/capacitor-backed cache) so the cache is honest by construction, not by configuration.

How do I test whether my storage actually loses unflushed writes?

Use dm-flakey with the drop_writes feature to silently discard writes on a schedule, run your workload against the mapped device, then restart and check recovery. Pair it with a fio --verify=crc32c run to see exactly which blocks disappear. If your application notices and recovers, you are durable; if it starts cleanly with wrong data, you are not.

Does the page cache affect durability testing?

Yes, heavily. Reads and writes hit the page cache by default, so a “durable” write can appear instant and a verification read can come from RAM instead of the device. Use --direct=1 in fio, O_DIRECT in application code, or drop caches between phases — our page cache inspection guide covers pcstat, vmtouch and fincore for proving what is actually resident.